11 types explained

Masks, respirators, filters and cartridges

Understand names, uses, limits, fit and care before dusty or chemical work.

A mask is not permission

Asbestos, lead, significant silica, isocyanates, unknown atmosphere, confined space, oxygen deficiency, smoke or carbon monoxide require assessment and often professionals. No air-purifying respirator supplies oxygen.

1. Control at source

Wet methods, HEPA extraction, local exhaust, isolation and less hazardous products come before PPE.

2. Identify contaminant

Particles, gases and vapours require different elements. Read the SDS and assess exposure.

3. Obtain a real seal

Facial hair in the seal area, wrong size or eyewear can cause leakage. Complete required fit testing and a user seal check every use.

4. Verify approval

Look for the NIOSH label and TC number; use facepiece, filters and cartridges in the approved configuration.

11 results

not respirator

Non-certified dust mask

Use
Comfort against some coarse nuisance dust only; no assigned protection.
Does not protect against
Silica, asbestos, lead, significant mould, fumes, gases, vapours or regulated work.
Fit
Does not replace a fitted, approved respirator.
Care
Disposable; do not present as certified respiratory PPE.
Replacement
Replace if dirty or damaged, but replacement does not make it approved.
not construction respirator

Medical or surgical mask

Use
Controls some droplets and splashes depending on product; it is not a tight-fitting construction respirator.
Does not protect against
Construction dust, silica, asbestos, solvent vapours, fumes or hazardous atmospheres.
Fit
Designed with edge leakage; no respirator fit test.
Care
Disposable according to manufacturer instructions.
Replacement
Replace if wet, soiled or damaged.
filtering facepiece

NIOSH Approved N95 filtering facepiece respirator

Use
At least 95% filtration of test particles; useful only for particles when exposure level and the respiratory program allow it.
Does not protect against
Gases, vapours, oxygen deficiency, unknown contaminant, fire or IDLH atmosphere.
Fit
Tight seal on clean-shaven skin, suitable model and size; user seal check every use and fit test where required.
Care
Disposable; do not wash. Store clean and dry per manufacturer.
Replacement
Replace if damaged, dirty, wet, difficult to breathe through or as required by manufacturer/program.
filtering facepiece

NIOSH Approved P100 filtering facepiece respirator

Use
99.97% particulate filtration and oil-proof classification; selection must be exposure-based.
Does not protect against
Gases, vapours, unknown or oxygen-deficient atmospheres. A P100 does not make asbestos or lead removal safe for an unqualified person.
Fit
Requires a facial seal, clean-shaven seal area and correct model/size selection.
Care
Disposable or model-specific; follow the complete approval configuration.
Replacement
Based on breathing resistance, damage, contamination and manufacturer limits.
elastomeric apr

Elastomeric half-mask with P100 filters

Use
Particles when compatible approved P100 filters are installed on the approved facepiece.
Does not protect against
Gases or vapours without the correct cartridge, oxygen deficiency, unknown contaminant or IDLH concentration.
Fit
Fit test, clean-shaven seal area and user seal check each use.
Care
Clean, disinfect, inspect valves and seals, dry and store in a clean container.
Replacement
Filters according to damage, contamination, breathing resistance and program/manufacturer schedule.
elastomeric apr combination

Half-mask with organic vapour cartridges and particulate prefilters

Use
Organic vapours named by the approval and particles, only when the cartridge matches the product and exposure.
Does not protect against
All solvents indiscriminately, isocyanates without a validated strategy, unknown, oxygen-deficient or IDLH atmospheres.
Fit
Fit test and facial seal required; eyewear and hair must not break the seal.
Care
Keep cartridges sealed when not in use; clean facepiece without immersing cartridges.
Replacement
Use a written change schedule based on manufacturer data and exposure; never rely on odour as the sole warning.
chemical cartridge

Specific acid-gas, ammonia or multi-gas cartridge

Use
Only contaminants explicitly listed by the approval and within service limits.
Does not protect against
Selection by colour alone, unknown products, unevaluated mixtures, oxygen-deficient or IDLH atmospheres.
Fit
Compatible facepiece, fit-tested and used in its approved configuration.
Care
Store airtight and follow cartridge-specific restrictions.
Replacement
Written change schedule required based on contaminant, concentration, humidity, temperature and duration.
full face elastomeric

Full-face elastomeric respirator

Use
Particles and/or certain gases/vapours with appropriate elements; also protects eyes from some irritants and splashes.
Does not protect against
Unknown, oxygen-deficient or IDLH atmospheres; does not replace supplied air.
Fit
Quantitative or program-compliant fit test, clean-shaven seal and compatible spectacle inserts.
Care
Detailed inspection of lens, valves, seals, straps, filters and cartridges.
Replacement
Filters/cartridges by schedule; facepiece repaired only with approved parts.
powered air purifying

Powered air-purifying respirator (PAPR)

Use
Powered protection against contaminants covered by the filter/cartridge; some loose-fitting hoods suit users who cannot use a tight face seal.
Does not protect against
Oxygen deficiency, unknown contaminant or IDLH, unless specifically approved—which generally requires supplied air/SCBA.
Fit
Tight-fitting models require fit testing; loose hoods have flow and inspection requirements.
Care
Check airflow, battery, alarm, hoses, hood, filter and cleaning before each use.
Replacement
According to airflow indicator, alarm, battery and filter/cartridge schedule.
supplied air

Supplied-air respirator

Use
Provides breathing air from a controlled source for certain high-exposure professional work.
Does not protect against
Improvised setup, non-breathing-air compressor or use without an appropriate program, monitoring and rescue plan.
Fit
Model-dependent; tight-fitting facepieces require fit testing.
Care
Breathing-air quality, hoses, fittings, alarms, airflow and source controlled under a professional program.
Replacement
Maintenance and inspection per manufacturer and program; no generic schedule.
self contained

Self-contained breathing apparatus (SCBA)

Use
Professional entry into certain IDLH atmospheres with appropriate equipment, training, monitoring and rescue plan.
Does not protect against
Residential DIY, untrained use or substitute for immediate evacuation.
Fit
Specialized program, fit testing, medical evaluation, training and rescue team.
Care
Regulated inspection, testing and maintenance by competent personnel.
Replacement
Cylinder and component management under a specialized program.

Pre-use check

  1. Known contaminant and concentration; no IDLH or oxygen-deficient atmosphere.
  2. Approved model, correct filter/cartridge and valid change date.
  3. Facepiece inspected, clean, with no damaged valve/seal.
  4. Seal area clean-shaven and no accessory breaks the seal.
  5. User seal check passed; valid fit test where required.
  6. Stop, ventilation, cleanup and decontamination plan prepared.

Verified references